There once was a project, I will call it BEN_old.
It had an interlinear set-up with many entries, and the results were automatically sent to a linked project (back translation) called BEN_ILR_old (the name mnemonics Interlinear-Results)
There was even a linked free translation, as some consultants do not like to read just interlinear strong-stuff. This one was called BEN_IFT_old (that name reminds of Interlinear-Free-Translation which would be a contradiction but reminds of the way those files are part of a work-flow).
Now for reasons that do not belong on the interweb, the project was forked and is now done by another organisation. For same reasons, the old names remained and new names were given to the forked files:
Main translation now called BEN_new.
And the interlinear data is still there, but I find no way to assign or send the results to BEN_ILR_new. When I try to open the interlinearizer, I get the well known welcome window from PT 9.2 and it still knows about the old setup (now under the name of the new main translation BEN_new) and wants to send all interlinear results to BEN_ILR_old.
When I try to create a new set-up, I get a dire warning like this:
The interinearizer can only use language data for one purpose at a time.
‘You have already created the following settings for the ‘BEN’ language:
Back translation of BEN_new[sic], Model text: RSV, Output: BEN_ILR_old
Would you like to replace these settings with the following:
Back translation of BEN_new, Model text: RSV, Output: BEN_ILR_new
During the forking-process, I had already created this BEN_ILR_new, based on the BEN_ILR_old. So I want to click YES.
But I would like to get confirmation from some people who understand the inner workings of PT, so that the team will not lose hundreds of work hours on the data.
Plan B:
I have looked around and found an XML file called InterlinearSetup.xml.
The structure is very clean and it is basically showing the one existing semi-old set-up where BEN_new is being interlinearized and results would still go to BEN_ILR_old.
The lines look hackable like this:
<ExportScrTextName>BEN_ILR_old</ExportScrTextName>
<ExportScrTextId>here a 40 digit guid which I could obtain from the online PT registry</ExportScrTextId>
Yet, I would never hack any XML file (with a shut-down PT of course) without first asking here in the forum.
So, please, what is a safe and recommended way to re-set-up our old proven set-up after the fork, with the knowledge in mind that the files have mainly been re-named for non-technical reasons and should still work together fine? Thank you.